LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Yukon Denali >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Transfer Case - NVG 246-NP8 - Service & Diagnosis) >> Repair Instructions >> Transfer Case Encoder Motor Replacement >> Removal Procedure

Removal Procedure

WARNING: This page is about a different variant/trim than selected.
    Fig 1: Identifying External Transfer Case Components
    GM829147Courtesy of GENERAL MOTORS CORP.
  1. Remove the transfer case shield, if equipped. Refer to Transfer Case Shield Replacement .
  2. Remove the front propeller shaft. Refer to Propeller Shaft Replacement - Front in Propeller Shaft.
  3. Disconnect the transfer case switch electrical connector (2).
  4. Disconnect the encoder motor electrical connector (7).
  5. Fig 2: Removing Encoder Motor Bolts
    GM857301Courtesy of GENERAL MOTORS CORP.
  6. Remove the encoder motor bolts.
  7. Remove the encoder motor.
  8. Remove the actuator insulator gasket.
  9. If replacing the encoder motor, remove the locating pins from the old motor.