Circuit Description
WARNING: This page is about a different variant/trim than selected.
Pressure control solenoid 2 (PCS2) is used to control on-coming, off-going, and holding pressure to any 1 of the 5 clutches. This solenoid is referred to as a pressure proportional to current (PPC) solenoid since the output hydraulic pressure supplied by this solenoid is proportional to the controlled current command.
The transmission control module (TCM) uses information from the turbine and output speed sensors (OSS) to detect if a clutch is in a tie-up condition or 3 clutches are applied. The clutch being controlled by PCS2 will vary, depending on the shift being made.
DTC P0777 is a type A DTC.