Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
P0602
- The ECM has not been programmed at Key On and Engine Off for 0.1 second.
- This diagnostic runs continuously.
P0606
- The ECM detects a microprocessor undervoltage or overvoltage condition.
OR
- The ECM detects an internal bus communication error.
OR
- The ECM detects an internal clock error.
OR
- The ECM detects an internal injector control error.
- All tests run in less than 1 second.
- This DTC runs continuously.
P060B
- The ECM detects an incorrect internal analog/digital (A/D) signal for less than 1 second.
- This DTC runs continuously.
P061C
- The ECM detects that there is a difference between the CKP engine speed and the calculated engine speed of more than 320 RPM for less than 1 second.
- This diagnostic runs continuously.
P062C
- The ECM detects a fault in the ship that calculates redundant vehicle speed for more than 1 second.
- This DTC runs continuously.
P062F
- The ECM did not complete the last electronic erasable programmable read only memory (EEPROM) write event during the last ECM power down.
- This diagnostic runs once per ignition cycle at power up.
P2610
- The ignition off-timer is less than 0 second.
OR
- The ignition off-timer is less than 5 seconds for more than 10 seconds.
OR
- The ignition off-timer is unchanged for 60 seconds.
OR
- The ignition off-timer is not incrementing in 1-second intervals.