Installation Procedure
WARNING: This page is about a different variant/trim than selected.
IMPORTANT:
Ensure to point the arrow on the MAF/IAT sensor away from the air cleaner box.
- Install the MAF/IAT sensor.
NOTE: Refer to FASTENER NOTICE in Cautions and Notices.
- Tighten the MAF/IAT sensor clamp at the air cleaner box.
Tighten: Tighten the clamp to 4 N.m (35 lb in).
- Install the air cleaner outlet duct to the MAF/IAT sensor.
- Tighten the air cleaner outlet duct clamp at the MAF/IAT sensor.
Tighten: Tighten the clamp to 4 N.m (35 lb in).
- Connect the MAF/IAT sensor electrical connector (4).