Typical Scan Tool Data
WARNING: This page is about a different variant/trim than selected.
Cam Signal Present
| Circuit |
Normal Range |
Short to Ground |
Open |
Short to Voltage |
| Operating Conditions:
Engine running |
| CMP 5-Volt Reference Voltage |
Yes |
No |
No |
Yes |
| CMP Sensor Signal |
Yes |
No |
No |
No |
| CMP Low Reference |
Yes |
- |
No |
- |