Tools Required
WARNING: This page is about a different variant/trim than selected.
J 21867 Pressure Gage
- Inspect the transmission for proper fluid level. Refer to Transmission Fluid Checking Procedure .
- Install a scan tool.
- Start the engine.
- Use the scan tool to inspect for any stored or active diagnostic trouble codes. Make necessary repairs.
- Turn the engine OFF, with the ignition ON.
- Remove the pressure plug from the line pressure test port.
- Install the J 21867 to the line pressure test port.
- Access the scan tool output control for the secondary fluid pump relay.
- Command the relay ON.
- Record the maximum pressures achieved.
- Secondary fluid pump pressure should be 110-275 kPa (16-40 psi).
- If the secondary fluid pump pressures vary greatly from the specifications, refer to High or Low Secondary Fluid Pump Pressure (M33 Only) .
- Remove the J 21867 .
- Install the pressure plug.
Tighten: Tighten the pressure plug to 8-14 N.m (6-10 lb ft).
IMPORTANT:
Before performing the line pressure check, verify that the secondary fluid pump and pump relay are operating correctly.
IMPORTANT:
It may be necessary to remove or disconnect components in order to gain access to the transmission line pressure test port/plug.
NOTE:
The secondary fluid pump assembly must be operated only when adequate automatic transmission fluid supply is present. Failure to do so may permanently damage the pump.
IMPORTANT:
In order to obtain acceptable secondary fluid pump pressure readings, it is recommended that several readings be taken.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.