LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Sierra 1500 HD, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 16 (Automatic Transmission - 4L60-E/4L65-E/4L70-E - Service, Diagnosis & Troubleshooting) >> Line Pressure Check Procedure (M33 Only) >> Tools Required

Tools Required

WARNING: This page is about a different variant/trim than selected.

J 21867  Pressure Gage

Fig 1: Using Pressure Gage To Test Line Pressure
GM1486667Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: Before performing the line pressure check, verify that the secondary fluid pump and pump relay are operating correctly.
  1. Inspect the transmission for proper fluid level. Refer to Transmission Fluid Checking Procedure .
  2. Install a scan tool.
  3. Start the engine.
  4. Use the scan tool to inspect for any stored or active diagnostic trouble codes. Make necessary repairs.
  5. Turn the engine OFF, with the ignition ON.
  6. IMPORTANT: It may be necessary to remove or disconnect components in order to gain access to the transmission line pressure test port/plug.
  7. Remove the pressure plug from the line pressure test port.
  8. Install the J 21867  to the line pressure test port.
  9. Access the scan tool output control for the secondary fluid pump relay.
  10. NOTE: The secondary fluid pump assembly must be operated only when adequate automatic transmission fluid supply is present. Failure to do so may permanently damage the pump.
    IMPORTANT: In order to obtain acceptable secondary fluid pump pressure readings, it is recommended that several readings be taken.
  11. Command the relay ON.
  12. Record the maximum pressures achieved.
  13. Secondary fluid pump pressure should be 110-275 kPa (16-40 psi).
  14. If the secondary fluid pump pressures vary greatly from the specifications, refer to High or Low Secondary Fluid Pump Pressure (M33 Only) .
  15. Remove the J 21867  .
  16. NOTE: Refer to Fastener Notice in Cautions and Notices.
  17. Install the pressure plug.

    Tighten:  Tighten the pressure plug to 8-14 N.m (6-10 lb ft).