LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Sierra 1500 HD, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1554 (HVAC System - Automatic) >> Diagnostic Information and Procedures >> DTC B0228, B0413, B0423, or B3779 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2010 GMC Sierra, 2010 GMC Cab & Chassis Sierra, 2010 Chevrolet Silverado, and 2010 Chevrolet Cab & Chassis Silverado. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the harness connector at the appropriate actuator.
  2. Test for less than 10 ohms between the low reference circuit terminal 7 and ground.
    • If greater than the specified range, test the low reference circuit for an open/high resistance.
  3. Ignition ON, test for 4.8-5.2 volts between the 5-volt reference circuit terminal 10 and ground.
    • If less than the specified range, test the 5-volt reference circuit for a short to ground or an open/high resistance.
    • If greater than the specified range, test the 5-volt reference circuit for a short to voltage.
  4. Verify the appropriate scan tool parameter is greater than 250 counts.
    • If greater than the specified range, test the signal circuit terminal 9 for a short to ground.
  5. Install a 3-amp fused jumper wire between the signal circuit terminal 9 and the low reference circuit terminal. Verify the appropriate scan tool parameter is less than 4 counts.
    • If less than the specified range, test the signal circuit for a short to voltage or an open/high resistance.
  6. Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 5 and ground.
    • If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.
  7. Install a DMM between the actuator control circuit terminal 6 and ground. While monitoring the DMM, use the scan tool to command the appropriate actuator from one direction to the other. The voltage on the control circuit should move from 0 volts in one direction to 5 volts in the other direction and 2.5 volts in the at rest state.
    • If the voltage does not change, test the control circuit for an open, short to voltage or short to ground. If circuit tests normal replace the HVAC control module.
  8. If all circuits test normal, replace the actuator.