Circuit/System Testing
WARNING: This page is about a different car, the 2010 GMC Sierra, 2010 GMC Cab & Chassis Sierra, 2010 Chevrolet Silverado, and 2010 Chevrolet Cab & Chassis Silverado. However, it is still accessible from the selected car via links, so may be relevant.
Sun Load Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the sunload sensor.
- Test for less than 10 ohms between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, test for 4.8-5.2 volts between the ground circuit terminal C and the appropriate signal circuit terminal listed below:
- Left solar load sensor circuit terminal A.
- Right solar load sensor circuit terminal B.
- If less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the sunload sensor.
IMPORTANT:
If a solar load sensor has an out of range condition caused by a short to voltage, short to ground, or an open/high resistance, the scan tool will display the same value: 225 counts.
Ambient Air Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the ambient temperature sensor.
- Test for less than 10 ohms between the low reference circuit terminal B and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the scan tool Outside Air Temp. Raw parameter is greater than 85°C (185°F).
- If less than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3-amp fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Outside Air Temp. Raw parameter is less than -35°C (-39°F).
- If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the ambient temperature sensor.
Inside Air Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate inside air temperature sensor.
- Test for less than 10 ohms between the ground circuit terminal C and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify a test lamp illuminates between the control circuit terminal B and ground.
- If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance.
- Ignition OFF, test for less than 10 ohms between the low reference circuit terminal D and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the appropriate scan tool Inside Temp Sensor parameter is greater than 85°C (185°F).
- If less than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3-amp fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Temp Sensor Voltage parameter is less than -35°C (-39°F).
- If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the appropriate temperature sensor.
Duct Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate temperature sensor.
- Test for less than 10 ohms between the low reference circuit terminal A and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the appropriate Duct Temp Sensor Actual parameter is greater than 85°C (185°F).
- If less than the specified range, test the signal circuit terminal B for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3-amp fused jumper wire between the signal circuit terminal B and the low reference circuit terminal A. Verify the scan tool Duct Temp Sensor Actual parameter is less than -35°C (-39°F).
- If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the appropriate temperature sensor.
IMPORTANT:
If the evaporator air temperature sensor has an out of range condition caused by a short to voltage, short to ground, or an open/high resistance, the scan tool will display the same value: 11°C (51°F).
Evaporator Air Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the evaporator air temperature sensor.
- Ignition OFF, test for less than 10 ohms between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, test for 4.8-5.2 volts between the signal circuit terminal 1 and low reference circuit terminal 2.
- If less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the evaporator air temperature sensor.