LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Sierra 1500 HD, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1342 (Hybrid Energy Storage System) >> Diagnostic Information and Procedures >> DTC P0ADF or P0AE0 >> Component Testing

Component Testing

WARNING: This page is about a different car, the 2009 GMC Sierra and 2009 Chevrolet Silverado. However, it is still accessible from the selected car via links, so may be relevant.
    WARNING: Always perform the High Voltage Disabling procedure prior to servicing any High Voltage component or connection. Personal Protection Equipment (PPE) and proper procedures must be followed.
    The High Voltage Disabling procedure will perform the following tasks:
    • Identify how to disable high voltage.
    • Identify how to test for the presence of high voltage.
    • Identify condition under which high voltage is always present and personal protection equipment (PPE) and proper procedures must be followed.

    Failure to follow the procedures exactly as written may result in serious injury or death.
  1. Ignition OFF, disable the high voltage at the drive motor generator battery. Refer to High Voltage Disabling .
  2. Remove the drive motor generator battery cover. Refer to Drive Motor Battery Case Upper Cover, Front Cover, and Right Side Cover Replacement .
  3. Disconnect the X1 harness connector at the negative contactor relay.
  4. Test for 23-29 Ω at 20°C (68°F) between the cotnrol terminal 1 and the ground terminal 2 of the negative contactor relay.
    • If not within the specified range, replace the negative contactor relay.