Forward Flushing Setup
WARNING: This page is about a different car, the 2008 Cadillac CTS. However, it is still accessible from the selected car via links, so may be relevant.
IMPORTANT:
Flushing is not intended to remove metal from the A/C system.
Flushing is intended to remove the following:
- Contaminated polyalkylene glycol (PAG) oil
- Desiccant, following a desiccant bag failure
- Overcharge of PAG oil
- Refrigerant contamination
- Forward flow refrigerant flushing is recommended for contaminated refrigerant or PAG oil.
- Inspect and lubricate the J 45268 fitting O-rings. See Special Tools . Refer to O-Ring Replacement .
- Install the J 45268-7 (2) onto the suction line adapter block J 45268-13 (1).
- Install the J 45268-8 (3) onto the discharge line adapter block J 45268-12 (4).
IMPORTANT: