LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Sierra 1500 HD, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1045 (Engine Controls And Fuel - 4.3L - DTC P0016 To DTC P0336) >> DTC P0230 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2008 GMC Sierra and 2008 Chevrolet Silverado. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the fuel pump relay.
  2. Ignition ON, verify that a test lamp illuminates between the ground circuit terminal and B+.
    • If the test lamp does not illuminate, test the ground circuit for a short to voltage or an open/high resistance.
  3. Verify that a test lamp does not illuminate between the ground circuit terminal and the control circuit terminal.
    • If the test lamp illuminates, test the control circuit for a short to voltage. If the circuit tests normal, replace the ECM.
  4. Remove the test lamp.
  5. Command the fuel pump relay ON with a scan tool. Verify the scan tool fuel pump relay Ckt. Short Grnd Test Status parameter is OK.
    • If not the specified value, test the fuel pump relay control circuit for a short to ground. If the circuit tests normal, replace the ECM.
  6. Install a 3A fused jumper wire between the fuel pump relay control circuit terminal and the ground circuit terminal. Command the fuel pump ON with a scan tool. Verify the scan tool fuel pump relay Ckt. Short Grnd Test Status parameter is Fault.
    • If not the specified value, test the fuel pump relay control circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
  7. If all circuits test normal, test or replace the fuel pump relay.