LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Sierra 1500 HD, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1027 (Power Take-Off System) >> Diagnostic Information and Procedures >> DTC P260A-P260C (PTO) >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different car, the 2008 GMC Sierra, 2008 GMC Cab & Chassis Sierra, 2008 Chevrolet Silverado, and 2008 Chevrolet Cab & Chassis Silverado. However, it is still accessible from the selected car via links, so may be relevant.
  1. Ignition OFF, disconnect the PTO relay.
  2. Igniton ON, test for 11 volts or greater between the PTO relay supply voltage circuit terminal 86 and ground.
    • If less than the specified voltage, test the PTO relay supply voltage circuit for a short to ground or an open/high resistance.
  3. Ignition OFF, disconnect the harness connector at the PTO module.
  4. Ignition ON, test for 0 volts between the PTO relay coil control circuit terminal 28 and ground.
    • If greater than the specified value, test the PTO relay control circuit for a short to voltage.
  5. Ignition OFF, connect the PTO relay.
  6. Ignition ON, test for 11 volts or greater between the PTO relay coil control circuit terminal 28 and ground.
    • If less than the specified voltage, test the PTO relay coil control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the PTO relay.