LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2006 >> Sierra 1500 HD, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1683 (Automatic Transmission - ALLISON - Description And Operation) >> Description and Operation >> Automatic Transmission Hydraulic Diagrams >> Second Range (Without TCC Applied) >> Notes

Second Range (Without TCC Applied): Notes

WARNING: This page is about a different car, the 2010 GMC Sierra, 2010 GMC Cab & Chassis Sierra, 2010 Chevrolet Silverado, and 2010 Chevrolet Cab & Chassis Silverado. However, it is still accessible from the selected car via links, so may be relevant.

Before shifting from first to second range, the transmission control module (TCM) makes certain shift valve 1, shift valve 2, and shift valve 3 are in the correct position with shift valve 1 and shift valve 2 de-stroked and shift valve 3 stroked.

Pressure control solenoid 1 (PCS1) is energized, opening PCS1 signal pressure to exhaust and allowing pressure control valve 1 to de-stroke, exhausting the low and reverse clutch pressure. PCS2 is energized, raising PCS2 signal and PCS2 pressures. The PCS2 pressure is directed through shift valve 1 and shift valve 3 to the 2-6 clutch. The TCM provides current to PCS2, which controls the rate at which the pressure control valve 2 supplies pressure to the 2-6 clutch, and current to PCS1, which controls the rate at which the low and reverse clutch is exhausted, assuring a smooth transition to second range. Main pressure continues to feed through shift valve 3 and the manual selector valve, keeping the 1-2-3-4 clutch applied.

The combination of the 1-2-3-4 and the 2-6 clutch application produces second range operation.

After the shift to second range is complete, SS2 is de-energized allowing shift valve 2 to de-stroke. The low and reverse clutch feed, which was exhausted through shift valve 2 and the PCS1, now exhausts through exhaust backfill, keeping the low and reverse clutch released. The 3rd, 5th, and reverse clutch has an exhaust path through shift valve 2 to the pressure control valve 1, keeping the 3rd, 5th, and reverse clutch released.

Pressure switch 1, pressure switch 2, and pressure switch 3 turn off, providing feedback that the valves are in the de-stroked position.

If electrical power is interrupted while the transmission is in second range, PCS1 and PCS2 de-energize. Normally open PCS2 exhausts the PCS2 signal pressure, allowing pressure control valve 2 to de-stroke, exhausting the 2-6 clutch. Normally closed PCS1 blocks the exhaust of the pressure control valve 1 signal pressure, allowing the PCS1 signal and PCS1 pressures to rise. Pressure control valve 1 directs full pressure through shift valve 2 to the 3rd, 5th, and reverse clutch, applying the clutch. The 1-2-3-4 clutch continues to be applied with main pressure through shift valve 3 and the manual selector valve. The combination of the 1-2-3-4 clutch and the 3rd, 5th, and reverse clutch applied produces third range converter operation for limp home capability.

If the torque converter clutch was applied during the power interrupt, the TCC solenoid is de-energized and the transmission returns to converter operation.

If electrical power is interrupted while the transmission is in second range and subsequent third range operation, moving the manual selector valve to Neutral (N) will cut off main pressure to the 1-2-3-4 clutch and the clutch will be exhausted. The 3rd, 5th, and reverse clutch remains applied. Because only one clutch is applied, the transmission goes to neutral.

If electrical power is interrupted while the transmission is in second range with subsequent third range operation, moving the manual selector valve to reverse will cut off main pressure to the 1-2-3-4 clutch, exhausting the 1-2-3-4 clutch. The manual selector directs main pressure through the TCC valve and shift valve 2 to the low and reverse clutch, applying the clutch. The 3rd, 5th and reverse clutch remains applied. The combination of the 3rd, 5th, and reverse clutch and the low and reverse clutch application produces reverse range operation for limp home capability.