Circuit Description
WARNING: This page is about a different car, the 2003 GMC Yukon XL, 2003 Chevrolet Suburban, and 2003 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
The 2-3 shift solenoid (SS) valve controls fluid flow acting on the 2-3 shift valves. The 2-3 SS valve is a normally-open exhaust valve used with the 1-2 SS valve in order to allow for four different shift combinations.
If the powertrain control module (PCM) detects a non third gear ratio while third gear is commanded, then DTC P0757 sets. DTC P0757 is a type C DTC. For California emissions vehicles and vehicles under 8,600 GVW, DTC P0757 is a type A DTC.