Air Speed (Auxiliary): Notes
There are 2 separate control assemblies for the auxiliary HVAC system. There is the front auxiliary HVAC control assembly and the rear auxiliary HVAC control assembly. Both control assemblies provide input to the auxiliary HVAC control processor. If the front auxiliary HVAC control assembly is in any other position than OFF or REAR, the auxiliary HVAC control processor will only use inputs from the front HVAC controls. If the front auxiliary HVAC control assembly is in the REAR position, then the system will only function with inputs from the rear auxiliary HVAC control assembly. If the front auxiliary HVAC control assembly is in the OFF position, then the auxiliary HVAC control processor does not respond to input from either control assembly. The auxiliary HVAC control processor can not request A/C compressor clutch engagement from the PCM. The rotary switches on the auxiliary HVAC control assembly and the front auxiliary HVAC control assembly provide the operator the ability to select several blower speeds.