Installation Procedure
WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
- Inspect the CMP actuator solenoid valve seal for damage. Replace the seal if necessary.
- Install the CMP actuator solenoid valve.
- Install the CMP actuator solenoid valve bolt. Tighten the bolt to 10 N.m (89 lb in).
- Connect the engine wiring harness electrical connector (2) to the bank 1 intake CMP actuator solenoid valve (5).
- Install the air cleaner assembly. Refer to Air Cleaner Assembly Replacement .
CAUTION:
Refer to Fastener Caution
.