- Ignition OFF, disconnect the affected relay.
- Verify that a test lamp illuminates between the B+ circuit terminal 85 and ground:
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and its fuse is open, test the control circuit terminal 87 for a short to ground. If the circuit tests normal, replace the relay.
- Test for 70-110 ohms between terminal 85 and terminal 86 of the relay.
- If not within the specified range, replace the relay.
- Test for 0.0A with a DMM connected in series with the relay coil between circuit terminal 85 and circuit terminal 86 at the relay connector.
- If more than the specified value, test the control circuit terminal 86 for a short to ground. If the circuit tests normal, replace the ECM.
- Command the relay ON with a scan tool. Verify that the DMM indicates more than 100 mA.
- If not the specified range, test the control circuit terminal 86 for an open/high resistance. If the circuit tests normal, replace the ECM.