Circuit/System Verification
WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
- Measure actual outside air temperature using a thermometer. Compare this value to the scan tool Outside Air Temp. Raw parameter. The measured temperature should be within 5 degrees of parameter.
- If not within the specified range, refer to Ambient / Inside Air Temperature Sensor Circuit Malfunction.
- Measure actual inside air temperature using a thermometer. Compare this value to the scan tool Inside Air Temp. parameter. The measured temperature should be within 5 degrees of parameter.
- If not within the specified range, refer to Ambient Temperature Sensor Circuit Malfunction.
- Measure actual temperature using a thermometer at the A/C evap. temperature sensor. Compare this value to the scan tool A/C Evap. Temperature Sensor parameter. The measured temperature should be within 5 degrees of the parameter.
- If not within the specified range, refer to Evaporator Temperature Sensor Circuit Malfunction.
Ambient Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate temperature sensor.
- Test for less than 1 ohm between the low reference circuit terminal B and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the appropriate scan tool Temp Sensor Voltage parameter is greater than 4.9 volts or 250 counts.
- If less than the specified range, test the signal circuit terminal A for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3-amp fused jumper wire between the signal circuit terminal A and the low reference circuit terminal B. Verify the scan tool Temp Sensor Voltage parameter is less than 0.1 volt or 5 counts.
- If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the appropriate temperature sensor.
Evaporator Temperature Sensor Circuit Malfunction
- Ignition OFF, disconnect the harness connector at the appropriate temperature sensor.
- Test for less than 1.0 ohm between the low reference circuit terminal 2 and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- Ignition ON, verify the appropriate Temperature Sensor parameter is greater than 4.9 volts or 250 counts.
- If less than the specified range, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the HVAC control module.
- Install a 3-amp fused jumper wire between the signal circuit terminal 1 and the low reference circuit terminal 2. Verify the Scan Tool Temperature Sensor parameter is less than 0.1 volt or 5 counts.
- If greater than the specified range, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the HVAC control module.
- If all circuits test normal, test or replace the appropriate temperature sensor.