Test Description
WARNING: This page is about a different car, the 2009 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
The numbers below refer to the step numbers on the diagnostic table.
- 1: This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
- 2: This step measures the performance of the A/C system.
- 3: This step is to allow for vehicle variations as well as high ambient temperatures.
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
|
IMPORTANT:
|
||||
| 1 |
|
More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) |
Go to Step 2 | Go to Leak Testing (With HP5) or Leak Testing (Without HP5) |
| 2 |
IMPORTANT:
Record the relative humidity and the ambient air temperature at the time of the test.
IMPORTANT:
Press the RESET button, before using the print function of the J 43600
. See Special Tools .
|
- | Go to Step 8 | Go to Step 3 |
| 3 | If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C Performance Table? |
- | Go to Step 8 | Go to Step 4 |
| 4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone A (with HP5) or Air Conditioning (A/C) Diagnostics - Pressure Zone A (without HP5) | Go to Step 5 |
| 5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone B | Go to Step 6 |
| 6 | Are the low and high side pressures both greater than the specified ranges? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone C | Go to Step 7 |
| 7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | - | Go to Air Conditioning (A/C) Diagnostics - Pressure Zone D (without HP5) or Air Conditioning (A/C) Diagnostics - Pressure Zone D (with HP5) | Go to Step 8 |
| 8 | Operate the system in order to verify the test results. Did you find the same results? |
- | System OK | Go to Symptoms - HVAC Systems - Manual |
A/C Performance Table
| Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
|---|---|---|---|---|
| 13-18°C (55-65°F) | 0-100% | 151-234 kPa (22-34 psi) | 1109-1619 kPa (161-235 psi) | 8°C (45°F) |
| 19-24°C (66-75°F) | Below 40% | 151-213 kPa (22-31 psi) | 1019-1481 kPa (148-215 psi) | 11°C (51°F) |
| Above 40% | 151-261 kPa (22-38 psi) | 1247-1701 kPa (181-247 psi) | 10°C (50°F) | |
| 25-29°C (76-85°F) | Below 35% | 151-2348 kPa (22-34 psi) | 1267-1598 kPa (184-232 psi) | 13°C (54°F) |
| 35-50% | 172-254 kPa (25-37 psi) | 1378-1681 kPa (200-244 psi) | 13°C (54°F) | |
| Above 50% | 186-282 kPa (27-41 psi) | 1460-1770 kPa (212-257 psi) | 13°C (55°F) | |
| 30-35°C (86-95°F) | Below 30% | 179-268 kPa (26-39 psi) | 1440-1756 kPa (209-255 psi) | 14°C (57°F) |
| 30-50% | 192-282 kPa (28-41 psi) | 1502-1791 kPa (218-260 psi) | 15°C (59°F) | |
| Above 50% | 213-303 kPa (31-44 psi) | 1570-1853 kPa (228-269 psi) | 17°C (61°F) | |
| 36-41°C (96-105°F) | Below 20% | 213-269 kPa (31-43 psi) | 1639-1942 kPa (238-282 psi) | 18°C (63°F) |
| 20-40% | 220-303 kPa (32-44 psi) | 1660-1942 kPa (241-282 psi) | 18°C (63°F) | |
| Above 40% | 234-316 kPa (34-46 psi) | 1701-1929 kPa (247-280 psi) | 18°C (64°F) | |
| 42-46°C (106-115°F) | Below 20% | 254-330 kPa (37-48 psi) | 1860-2108 kPa (270-306 psi) | 18°C (64°F) |
| Above 20% | 254-330 kPa (37-48 psi) | 1860-2094 kPa (270-304 psi) | 19°C (66°F) | |
| 47-49°C (116-120°F) | Below 30% | 289-358 kPa (42-52 psi) | 2032-2273 kPa (295-330 psi) | 22°C (70°F) |