Installing Manifold Gage Set
WARNING: This page is about a different car, the 2003 Saturn Vue. However, it is still accessible from the selected car via links, so may be relevant.
If an A/C system problem still exists after you have completed the preliminary inspects, more diagnostic tests must follow. These include manifold gage set readings. Follow the steps listed below for installing a manifold gage set.
- Close both hand valves of manifold gage set.
- Connect low pressure (blue) gage hose to suction service port located on the suction pipe. Pull valve assembly collar up, place valve assembly over service port and release collar.
- Open service valve.
- Connect high pressure (red) gage hose to discharge service port located on the liquid line. Pull valve assembly collar up, place valve assembly over service port and release collar.
- Open service valve.
CAUTION:
Always wear goggles and wrap a clean cloth around fittings, valves, and connections when performing work that involves opening the refrigerant system.
IMPORTANT:
Inspect to make sure gages read zero before installing manifold gage set.