Diagnostic Aids
WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2002 GMC Yukon XL, 2002 GMC Yukon, 2002 Chevrolet Tahoe, 2002 Chevrolet Suburban, and 2002 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
- The range fault can only be detected following a recalibration. The recalibration can only be initiated by removing the battery positive voltage circuit to the HVAC control module.
- The calibration limit is 64-216 counts. An actual range below this limit suggests an obstruction, something stuck in the door limiting travel. An actual range above this limit suggests an over travel condition, damaged or missing foam seals.
- A damaged or broken auxiliary air temperature door and or actuator can cause this DTC to set.
- If condition not present refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS .
DTC B0434
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics | ||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
64-216 Counts | Go to Step 3 | Go to Step 8 |
| 3 |
|
5-250 Counts | Go to TESTING FOR INTERMITTENT AND POOR CONNECTIONS | Go to Step 4 |
| 4 | Test the ground circuit of the auxiliary air temperature actuator for an open. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 5 |
| 5 | Test the 5 volt reference circuit of the auxiliary air temperature actuator for a short to ground or short to voltage. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 6 |
| 6 | Test the signal circuit of the auxiliary air temperature actuator for an open, high resistance, short to ground or short to voltage. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 7 |
| 7 |
IMPORTANT:
The auxiliary air temperature actuator connector and the auxiliary HVAC control module connector must be connected to correctly perform test.
|
- | Go to Step 10 | Go to Step 9 |
| 8 | Inspect the auxiliary air temperature door and the auxiliary air temperature actuator for the following:
Did you find and correct the condition? |
- | Go to Step 13 | Go to Diagnostic Aids |
| 9 | Inspect for poor connections at the harness connector of the auxiliary air temperature actuator. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 11 |
| 10 | Inspect for poor connections at the harness connector of the auxiliary HVAC control module. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 12 |
| 11 | Replace the auxiliary air temperature actuator. Refer to AIR TEMPERATURE ACTUATORS - AUXILIARY
. Did you complete the replacement? |
- | Go to Step 13 | - |
| 12 | Replace the auxiliary HVAC control module. Refer to HVAC Control Module Replacement - Auxiliary . Did you complete the replacement? |
- | Go to Step 13 | - |
| 13 |
|
- | Go to Step 2 | System OK |