WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2002 GMC Yukon XL, 2002 GMC Yukon, 2002 Chevrolet Tahoe, 2002 Chevrolet Suburban, and 2002 Chevrolet Avalanche. However, it is still accessible from the selected car via links, so may be relevant.
- A dead zone exists in a range 10 counts above or below the mode door max or mode door min positions. When the mode door actual data parameter is within the dead zone, the DTC will not set. If the mode door commanded data parameter differs from the mode door actual data parameter by 4 counts or more outside the dead zone, the DTC will set.
- A damaged or broken mode door and or actuator can cause this DTC to set.
DTC B0248
| Step | Action | Values | Yes | No |
|---|---|---|---|---|
| Schematic Reference: HVAC Schematics | ||||
| 1 | Did you perform the HVAC Diagnostic System Check? | - | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Automatic |
| 2 |
|
0-3 counts | Go to TESTING FOR INTERMITTENT AND POOR CONNECTIONS | Go to Step 3 |
| 3 |
|
5-250 counts | Go to Diagnostic Aids | Go to Step 4 |
| 4 | Test the mode door actuator ignition 3 circuit for an open. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 5 |
| 5 | Test the 5 volt reference circuit of the mode actuator for an open. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 6 |
| 6 | Test the mode door control circuit for an open, short to ground or short to voltage. Refer to CIRCUIT TESTING
and WIRING REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 7 |
| 7 |
IMPORTANT:
The mode actuator connector and the HVAC control module connector must be connected to correctly perform test.
|
- | Go to Step 13 | Go to Step 8 |
| 8 | Inspect the mode door and the mode actuator for the following:
Did you find and correct the condition? |
- | Go to Step 10 | Go to Step 9 |
| 9 | Inspect for poor connections at the harness connector of the mode actuator. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 11 |
| 10 | Inspect for poor connections at the harness connector of the HVAC control module. Refer to TESTING FOR INTERMITTENT AND POOR CONNECTIONS
and CONNECTOR REPAIRS
. Did you find and correct the condition? |
- | Go to Step 13 | Go to Step 12 |
| 11 |
IMPORTANT:
Perform the recalibration procedure for the mode actuator. Replace the mode actuator. Refer to Mode Actuator Replacement (W/ D07) or Mode Actuator Replacement (W/O D07) .Did you complete the replacement? |
- | Go to Step 13 | - |
| 12 |
IMPORTANT:
Perform the recalibration procedure for the HVAC control module. Replace the HVAC control module. Refer to HVAC Control Module Replacement .Did you complete the replacement? |
- | Go to Step 13 | - |
| 13 |
|
- | Go to Step 2 | System OK |