- 9: The HVAC control module is supplied by 2 ignition-3 voltage circuits. Test the ignition-3 voltage circuit that does not supply the blower motor switch.
Air Recirculation Malfunction
| Step | Action | Yes | No |
|---|---|---|---|
| Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Air recirculation is inoperative or is always ON. |
|||
| 1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Manual |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 | Except for the blower motor speed, are all of the functions of the HVAC control module inoperative? | Go to Step 9 | Go to Step 4 |
| 4 |
|
Go to Step 5 | Go to Step 15 |
| 5 | Test the ground circuit of the recirculation actuator for an open or for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 6 |
| 6 |
|
Go to Step 14 | Go to Step 7 |
| 7 | Test the door control circuit of the recirculation actuator for an open, for a high resistance, for a short to ground, or for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 8 |
| 8 | Inspect the recirculation door and the recirculation actuator for the following conditions:
Did you find and correct the condition? |
Go to Step 18 | Go to Step 13 |
| 9 | Test the ignition 3 voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 10 |
| 10 | Test the battery positive voltage circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 11 |
| 11 | Test the ground circuit of the HVAC control module for an open or for a high resistance. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 12 |
| 12 | Test the off blower motor control circuit of the HVAC control module for a short to voltage. Refer to Circuit Testing
and to Wiring Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 14 |
| 13 | Inspect for bad connections at the harness connector of the recirculation actuator. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 16 |
| 14 | Inspect for bad connections at the harness connector of the HVAC control module. Refer to Testing for Intermittent Conditions and Poor Connections
and to Connector Repairs
in Wiring Systems. Did you find and correct the condition? |
Go to Step 18 | Go to Step 17 |
| 15 | Repair the ignition 3 voltage circuit of the recirculation actuator. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 18 | - |
| 16 | Replace the recirculation actuator. Refer to Recirculation Actuator Replacement . Did you complete the replacement? |
Go to Step 18 | - |
| 17 | Replace the HVAC Control module. Refer to HVAC Control Module Replacement (Buick) or HVAC Control Module Replacement (Pontiac) . Did you complete the replacement? |
Go to Step 18 | - |
| 18 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |