DTC P1133: Ho2S Insufficient Switching (Bank 1; Sensor 1 - DOHC): Description
Heated Oxygen Sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the vehicle is first started, the Powertrain Control Module (PCM) operates in an open loop mode, ignoring the HO2S signal voltage when calculating the air/fuel ratio. The PCM supplies the HO2S with a reference, or bias, voltage of 450 millivolts. The HO2S generates a voltage within a range of 0-1000 millivolts, that fluctuates at greater than and less than bias voltage once in closed loop. High HO2S voltage output indicates a rich fuel mixture; low HO2S voltage output indicates a lean mixture. A heating element inside the HO2S reduces the time required for the sensor to reach operating temperature, and provide an accurate voltage signal.
The PCM monitors the rich-to-lean and lean-to-rich HO2S switching activity. This DTC will set if the HO2S voltage did not switch enough times during a calibrated time period.