DTC P0130: Ho2S Circuit - Sensor 1 (DOHC): Description
Heated Oxygen Sensors (HO2S) are used for fuel control and post catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the vehicle is first started, the Powertrain Control Module (PCM) operates in an open loop mode, ignoring the HO2S signal voltage when calculating the air/fuel ratio. The PCM supplies the HO2S with a reference, or bias, voltage of 450 millivolts. The HO2S generates a voltage within a range of 0-1000 millivolts, that fluctuates at greater than and less than bias voltage once in closed loop. A high HO2S voltage output indicates a rich fuel mixture. A low HO2S voltage output indicates a lean mixture. A heating element inside the HO2S reduces the time required for the sensor to reach operating temperature, and provide an accurate voltage signal. This DTC will set if the engine is not operating in closed loop for 5 seconds out of 12.5 seconds.
This DTC will set if the engine is not operating in closed loop for 5 seconds out of 12.5 seconds.