Installation Procedure
- Install the left molding to the door:
- 1.1. Place the retainers into the holes.
- 1.2. Press on the panel at the retainer locations until the retainers are fully seated.
- Install the right molding to the door:
- 2.1. Place the retainers into the holes.
- 2.2. Press on the panel at the retainer locations until the retainers are fully seated.
NOTE: Refer to FASTENER NOTICE in Cautions and Notices. - Install the screws that retain the panel to the door.
Tighten
Tighten the screws that retain the panel to the door to 2 N.m (18 lb in).
- Install the swing-out window latch. Refer to WINDOW REPLACEMENT - SWING OUT in Stationary Windows.
- Ensure that the weatherstrip fits into the corner and matches the corner of the radius of the body flange.
- Ensure that the weatherstrip is seated completely onto the flange in all areas, resulting in a smooth, vinyl trim around the entire door opening.
Important: When using the rubber mallet, the weatherstrip must be hit square to the flange. Otherwise, an undesirable spreading of the carrier will occur, resulting in reduced retention.
- Ensure that there is no distortion or excessive spreading of the carrier as a result of hitting the carrier improperly with the rubber mallet.
- Lubricate the weatherstrip with GM Weatherstrip Silicone Lubricant P/N 12345579 or equivalent.