Installation Procedure
- Position the insulator panel to the I/P.
- Install the hazard and turn signal flasher to the insulator panel. Refer to HAZARD AND TURN SIGNAL FLASHER REPLACEMENT in Lighting Systems.
- Install the splice pack to the insulator panel.
- Position the DLC to the insulator panel.NOTE: Refer to FASTENER NOTICE in Cautions and Notices.
- Install the DLC retaining screws.
Tighten
Tighten the DLC retaining screws to 2.5 N.m (22 lb in).
- Install the insulator panel tabs to the cowl slots.
- Raise the insulator panel to the I/P.
- Install the insulator panel retaining clip to the I/P substrate.
- Install the 2 screws that retain the insulator panel to the I/P.
Tighten
Tighten the screws to 2.5 N.m (22 lb in).