Removal Procedure

  1. Remove the power supply fuse.
  2. Lift up the front cover of the socket.
  3. Fig 1: Inserting J 42059
    GM378525Courtesy of GENERAL MOTORS COMPANY
  4. Insert the J 42059  into the socket sleeve. Tilt the tool so that the tool fits into the slots on the sides of the socket sleeve.
  5. Fig 2: Receptacle & Assembly
    GM378524Courtesy of GENERAL MOTORS COMPANY
  6. Hold the plastic ring in place. Pull the socket out of the assembly in order to remove the outlet.
  7. Fig 3: Identifying Grinding Tool
    GM1120988Courtesy of GENERAL MOTORS COMPANY
  8. If J 42059 tool fails to release the power port/lighter socket from the retainer, perform the following alternate method:
    1. Insert a small grinding tool with a cutoff wheel into the socket.
    2. Remove the plastic latches in the 3 mm (0.11 in) square windows.
    3. Use the J 42059  as directed above to remove the socket.
  9. Remove the electrical connector from the socket.