Reserve System
System consists of a charging valve, accumulator valve, and a spring loaded accumulator. Accumulator is integral with booster unit. System is open to pressure port of booster unit.
Charging valve has an orifice and ball check. Fluid from pump passes through orifice in valve, unseats ball check valve and enters accumulator. Ball check valve prevents reverse flow.
Accumulator valve is a poppet-type valve held closed by accumulator pressure. If no pump pressure is available, an actuator on spool valve sleeve opens accumulator valve. Fluid pressure can also enter accumulator from boost chamber through accumulator valve, when boost chamber pressure exceeds accumulator pressure.
A pressure relief valve vents accumulator to pump return port when pressure in accumulator exceeds approximately 1600 psi (112 kg/cm2 ).