DTC P0403 - EGR A Control Circuit/Open

WARNING: This page does not describe the selected car, but rather 24 other vehicles, including the 2019 Lincoln Navigator, 2019 Lincoln Nautilus, 2019 Lincoln MKZ, 2019 Lincoln MKT, and 2019 Lincoln MKC. However, it is still accessible from the selected car via links, so may be relevant.
DTC DESCRIPTION P0403 - EGR A CONTROL CIRCUIT/OPEN

Description:  The exhaust gas recirculation (EGR) system is continuously monitored to check the four electric EGR motor coils, circuits, and the PCM for opens, shorts to voltage and ground. If a concern is detected, the EGR system is disabled and additional monitoring is suspended for the remainder of the drive until the next drive cycle.
Possible Causes: 
  • Electric EGR stepper motor windings open
  • Electric EGR connector not seated correctly
  • EGRMC circuit open
  • EGRMC circuit short to voltage
  • EGRMC circuit short to ground
Diagnostic Aids: 
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST KD .