Home >> Ford >> 2022 >> Transit Connect Titanium, Gas/Ethanol >> Repair and Diagnosis >> External Pages >> Different car >> Section 701 (Electric Powertrain Control - 3.5L V6 POWERBOOST (CN) (Diagnosis & Testing - Removal & Installation)) >> Diagnosis And Testing >> Electric Powertrain Control >> Pinpoint Tests >> Pinpoint Test Av: P0DFA:00, P1A0E:62, P1A0E:64, P1A0E:96

Pinpoint Test Av: P0DFA:00, P1A0E:62, P1A0E:64, P1A0E:96

WARNING: This page is about a different car, the 2021 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
  1. Normal Operation and Fault Conditions 

    REFER to: Electric Powertrain Control - Component Location .

    DTC Fault Trigger Conditions 

    DTC Description Fault Trigger Condition
    SOBDMC P0DFA:00 Generator Phase U-V-W Current Sensor Correlation: No Sub Type Information This DTC sets when there is a current imbalance in the 3 Phase High Voltage AC cables.
    SOBDMC P1A0E:62 Hybrid Powertrain Control Module - Motor Disabled: Signal Compare Failure This DTC sets when the motor torque is out of range.
    SOBDMC P1A0E:64 Hybrid Powertrain Control Module - Motor Disabled: Signal Plausibility Failure This DTC sets when a plausibility fault with motor torque is detected.
    SOBDMC P1A0E:96 Hybrid Powertrain Control Module - Motor Disabled: Component Internal Failure This DTC sets when a motor phase current checksum error is detected.

    Possible Sources 

    • Wiring, terminals or connectors
    • Electric motor assembly
    • Inverter System Controller (ISC)

  2. AV1 CHECK THE INVERTER SYSTEM CONTROLLER (ISC) CALIBRATION LEVEL

    • Verify the Inverter System Controller (ISC) is at the latest calibration level.

    Is the Inverter System Controller (ISC) at the latest calibration level? 

    Yes  GO to  AV2
    No  UPDATE the Inverter System Controller (ISC) to the latest calibration level.
  3. AV2 VISUAL INSPECTION OF THE HIGH VOLTAGE SYSTEM

    • Ignition OFF.

    • Visually inspect all the high voltage cables.

    • Make sure all the high voltage connectors are correctly and securely connected.

    • Examine all the high voltage cables and connectors for damaged, burned or overheated insulation and loose or broken connections.

    Is a concern present? 

    Yes  REPAIR as necessary. CLEAR the DTCs and REPEAT the self-test.
    No  GO to  AV3
  4. AV3 TEST DRIVE THE VEHICLE

    • Ignition ON.

    • Clear the Inverter System Controller (ISC) DTCs.

    • Access the SOBDMC and monitor the GTQ_CMD (Nm) PIDand

      Access the SOBDMC and monitor the GTQ_OUT (Nm) PID

    • While monitoring the PIDs, road test the vehicle under load (above 4000 RPM) REFER to: Road Testing Vehicle .

    Are the generator torque command and generator torque out PID readings separated by greater than 18 lb.ft (25 Nm) ONLY above 4000 RPM? 

    Yes  GO to  AV5
    No  GO to  AV4
  5. AV4 CHECK FOR INVERTER SYSTEM CONTROLLER (ISC) DIAGNOSTIC TROUBLE CODES (DTCS)

    • Carry out the Inverter System Controller (ISC) self-test.

    Are DTCs P1A0E:62, P1A0E:64 or P1A0E:96 present? 

    Yes  CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new Inverter System Controller (ISC). REFER to: Inverter System Controller [SOBDMC] .
    No  GO to  AV5
  6. AV5 CHECK THE ELECTRIC MOTOR CIRCUITS FOR AN OPEN

    • Ignition OFF.

    • Disconnect Electric Motor C1201.

    • Disconnect Inverter System Controller (ISC) C1458B.

    Are the resistances less than 5 ohms? 

    Yes  GO to  AV6
    No  INSTALL new high voltage cables. REFER to: High Voltage Battery Cables . CLEAR the DTCs and REPEAT the self-test.
  7. AV6 CHECK THE ELECTRIC MOTOR CIRCUITS FOR A SHORT TO THE EXTERNAL CABLE SHIELD

    • Measure and record:
      Positive Lead Measurement / Action Negative Lead
      C1201-1
      GFD558202Courtesy of FORD MOTOR COMPANY
      C1201-Pin Shield
      C1201-2
      GFD558202Courtesy of FORD MOTOR COMPANY
      C1201-Pin Shield
      C1201-3
      GFD558202Courtesy of FORD MOTOR COMPANY
      C1201-Pin Shield

    Are the resistances greater than 10K ohms? 

    Yes  GO to  AV7
    No  INSTALL new high voltage cables. REFER to: High Voltage Battery Cables . CLEAR the DTCs and REPEAT the self-test.
  8. AV7 CHECK THE ELECTRIC MOTOR CIRCUITS FOR A SHORT TO GROUND

    • Measure and record:
      Positive Lead Measurement / Action Negative Lead
      C1201-1
      GFD558202Courtesy of FORD MOTOR COMPANY
      Ground
      C1201-2
      GFD558202Courtesy of FORD MOTOR COMPANY
      Ground
      C1201-3
      GFD558202Courtesy of FORD MOTOR COMPANY
      Ground

    Are the resistances greater than 10K ohms? 

    Yes  GO to  AV8
    No  INSTALL new high voltage cables. REFER to: High Voltage Battery Cables . CLEAR the DTCs and REPEAT the self-test.
  9. AV8 CHECK THE ELECTRIC MOTOR CIRCUITS FOR SHORTED TOGETHER

    • Measure and record:
      Positive Lead Measurement / Action Negative Lead
      C1201-1
      GFD558202Courtesy of FORD MOTOR COMPANY
      C1201-2
      C1201-1
      GFD558202Courtesy of FORD MOTOR COMPANY
      C1201-3
      C1201-2
      GFD558202Courtesy of FORD MOTOR COMPANY
      C1201-3

    Are the resistances greater than 10K ohms? 

    Yes  INSTALL a new electric motor. REFER to: Hybrid Drive Unit . CLEAR the Inverter System Controller (ISC) DTCs. REPEAT the self-test.
    No  INSTALL new high voltage cables. REFER to: High Voltage Battery Cables . CLEAR the DTCs and REPEAT the self-test.