Pinpoint Test S: The A/C (Air Conditioning) Compressor Relief Valve Discharging
WARNING: This page is about a different car, the 2021 Ford F-150. However, it is still accessible from the selected car via links, so may be relevant.
- Normal Operation and Fault Conditions
The A/C pressure relief valve normal open pressure is 3, 447-4, 137 kPa (500-600 psi).
Possible Sources
- High system pressure
- A/C pressure relief valve
- S1 DIAGNOSE THE A/C (AIR CONDITIONING) COMPRESSOR RELIEF VALVE
- Start the engine.
- On the HVAC controls, set the temperature to full cold, select PANEL and select the A/C button (indicator on).
- Using the appropriate manifold gauge set, check the A/C high side system pressure.
Is the high side system pressure above the A/C pressure relief valve open pressure [3, 447-4, 137 kPa (500-600 psi)]?
Yes REPAIR the A/C system for a restriction. REFER to the appropriate Refrigerant System Tests GENERAL PROCEDURES . No INSTALL a new A/C compressor. REFER to the appropriate REMOVAL AND INSTALLATION procedure.