Home >> Ford >> 2022 >> Transit Connect Titanium, Gas/Ethanol >> Repair and Diagnosis >> External Pages >> Different car >> Section 6 (Engine Controls - Powertrain DTC Charts & Descriptions (Except Diesel & Hybrid)) >> Diagnostic Trouble Code (DTC) Charts and Descriptions >> DTC P0403 - EGR A Control Circuit/Open

DTC P0403 - EGR A Control Circuit/Open

WARNING: This page does not describe the selected car, but rather 31 other vehicles, including the 2018 Lincoln Navigator, 2018 Lincoln MKZ, 2018 Lincoln MKX, 2018 Lincoln MKT, and 2018 Lincoln MKC. However, it is still accessible from the selected car via links, so may be relevant.
P0403 - EGR A CONTROL CIRCUIT/OPEN

Description:  The exhaust gas recirculation (EGR) system is continuously monitored to check the four electric EGR motor coils, circuits, and the PCM for opens, shorts to voltage and ground. If a concern is detected, the EGR system is disabled and additional monitoring is suspended for the remainder of the drive until the next drive cycle.
Possible Causes: 
  • Electric EGR stepper motor windings open
  • Electric EGR connector not seated correctly
  • EGRMC circuit open
  • EGRMC circuit short to voltage
  • EGRMC circuit short to ground
  • Damaged PCM
Diagnostic Aids: 
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All GO to PINPOINT TEST KD .