Normal Operation and Fault Conditions
WARNING: This page is about a different car, the 2019 Ford F-550 Super Duty, 2019 Ford F-450 Super Duty, 2019 Ford F-350 Super Duty, and 2019 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
The SASM requires an operating voltage between 8 and 17 volts. The SASM receives fused ignition voltage from the BCM run-start bus. The SASM sets this DTC if there is excessive resistance or an open in this circuit, including an open fuse.
DTC DESCRIPTION
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| U3011:13 | Ignition Input Off: Circuit Open | This DTC sets if the ignition voltage supplied to the SASM is below 6 volts for more than one second. |