Home >> Ford >> 2022 >> Transit Connect Titanium, Gas/Ethanol >> Repair and Diagnosis >> External Pages >> Different car >> Section 178 (Exterior Trim And Ornamentation) >> Diagnosis And Testing >> Power Running Board (PRB) >> Pinpoint Tests >> Pinpoint Test F : C1008:93, C1009:93, C1B14:11, C1B14:12 >> Notes

Pinpoint Test F : C1008:93, C1009:93, C1B14:11, C1B14:12: Notes

WARNING: This page is about a different car, the 2019 Ford F-550 Super Duty, 2019 Ford F-450 Super Duty, 2019 Ford F-350 Super Duty, and 2019 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.

Refer to Retractable Running Boards for schematic and connector information.

Normal operation and Fault Conditions 

TheRBM monitors the movement, position and current draw of each PRB with a hall-effect switch that is integral to each PRB motor. The RBM supplies a shared 10 volt controlled voltage and a shared ground circuit to the PRB motor hall-effect sensors, and receives separate sensor signals from the RH and LH hall-effect sensors. Voltage varies on the LEFT or RIGHT RB hall-effect signal circuit as the motor moves the PRB. An open or shorted circuit will set these DTC.

DTC Fault Trigger Conditions 

DTC Description Fault Trigger Conditions
C1008:93 Left Power Running Board Position/Motion Sensor: No Operation This DTC sets if the system voltage is between 9.5 - 16 volts, the LHPRB motion is commanded and the left RB hall effect signal circuit at the RBM does not change.
C1009:93 Right Power Running Board Position/Motion Sensor: No Operation This DTC sets if the system voltage is between 9.5 - 16 volts, the RHPRB motion is commanded and the right RB hall effect signal circuit at the RBM does not change.
C1B14:11 Sensor Supply Voltage A: Circuit Short To Ground This DTC sets if the system voltage is between 9.5 - 16 volts, any PRB motion is commanded and the hall effect power circuit at the RBM is less than 7.5 volts.
C1B14:12 Sensor Supply Voltage A: Circuit Short To Battery This DTC sets if the system voltage is between 9.5 - 16 volts, any PRB motion is commanded and the hall effect power circuit at the RBM is greater than 10 volts.

Possible Sources 

Visual Inspection and Diagnostic Pre-checks