LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2022 >> Transit Connect Titanium, Gas/Ethanol >> Repair and Diagnosis >> External Pages >> Different car >> Section 144 (Anti-Theft System - Perimeter) >> Diagnosis And Testing >> Perimeter Anti-Theft Alarm >> Symptom Chart >> Symptom Chart: Anti-Theft - Perimeter

Symptom Chart: Anti-Theft - Perimeter

WARNING: This page is about a different car, the 2018 Ford F-550 Super Duty, 2018 Ford F-450 Super Duty, 2018 Ford F-350 Super Duty, and 2018 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.

Diagnostics in this service information assume a certain skill level and knowledge of Ford-specific diagnostic practices. REFER to: Diagnostic Methods .

Condition Possible Sources Actions
The alarm system does not activate from an unauthorized entry at the hood Refer to the Pinpoint Test GO to Pinpoint Test A 
The alarm system does not activate from an unauthorized entry at a door Door ajar input DIAGNOSE the courtesy lamps not illuminating when a door is open. REFER to: Interior Lighting .
The alarm system does not activate from the intrusion sensor Refer to the Pinpoint Test GO to Pinpoint Test B 
The alarm system does not arm or no turn signals flash confirmation Refer to the Pinpoint Test GO to Pinpoint Test C 
No traffic horn output during alarm activation Horn output concern REFER to: Horn .
The alarm system falsely activates A valid PATS key read was NOT received when the ignition transitioned to RUN
Panic button pressed on a RKE transmitter
Door ajar input
Intrusion/tilt sensor input
Hood ajar input
An intermittent fault exists. Using a diagnostic scan tool, view the following BCM Parameter Identifications (PIDs) to identify and isolate the cause of the last alarm activation.
Most Recent Alarm Trigger Event (ALARM_EVT_1)
2nd Most Recent Alarm Trigger Event (ALARM_EVT_2)
3rd Most Recent Alarm Trigger Event (ALARM_EVT_3)
4th Most Recent Alarm Trigger Event (ALARM_EVT_4)
For a PID value of "Panic" causing the false alarm event, the system is operating correctly at this time. INSTRUCT the customer in the correct operation of the panic alarm feature. REFER to "Panic Alarm" in the Owner's Literature.
For a PID value of "Door Ajar" causing the false alarm event, DIAGNOSE the ajar switches. REFER to: Interior Lighting .
For a PID value of "Interior Motion Detected" or "Tilt Detected" causing the false alarm event, diagnose the intrusion/tilt sensor. GO to Pinpoint Test B 
For a PID value of "Hood Ajar" causing the false alarm event, diagnose the hood ajar switch. GO to Pinpoint Test D