Thermostat Housing: Removal
NOTE:
Removal steps in this procedure may contain installation details.
- Drain the cooling system. Refer to: Engine Cooling System Draining, Vacuum Filling and Bleeding .
- Remove the bolt and the accessory drive belt cover.
Torque
: 18 lb.ft (25 Nm)
-
NOTE: Cover the generator to prevent coolant contamination and possible damage to generator.
Release the clamps and disconnect the coolant hoses from the thermostat housing.
Use the General Equipment: Hose Clamp Remover/Installer
- Remove the bolts and the thermostat housing. Inspect the O-ring seal and replace if necessary.
Torque
: 89 lb.in (10 Nm)