Home >> Ford >> 2022 >> Mustang Mach 1 Premium, Automatic Trans >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 17 (Engine Cooling - 5.2L 32V Ti-VCT - Supercharged) >> Removal And Installation >> Degas Bottle >> Removal

Degas Bottle: Removal

WARNING: This page is about a different variant/trim than selected.
WARNING: Always allow the engine to cool before opening the cooling system. Do not unscrew the coolant pressure relief cap when the engine is operating or the cooling system is hot. The cooling system is under pressure; steam and hot liquid can come out forcefully when the cap is loosened slightly. Failure to follow these instructions may result in serious personal injury.
NOTE: Removal steps in this procedure may contain installation details.
  1. GFD717616Courtesy of FORD MOTOR COMPANY
    GFD130533Courtesy of FORD MOTOR COMPANY
    WARNING: When releasing the cooling system pressure, cover the coolant expansion tank cap with a thick cloth.

    Remove the pressure relief cap.

    GFD717593Courtesy of FORD MOTOR COMPANY
  2. Using general tools, clamp the lower degas bottle hose and syphon the coolant from the degas bottle.

    Use the General Equipment: Fluid Suction Gun

    Use the General Equipment: Locking Pliers

    GFD717617Courtesy of FORD MOTOR COMPANY
  3. Release the clamps and disconnect the coolant hoses. Use the General Equipment: Hose Clamp Remover/Installer
    GFD717618Courtesy of FORD MOTOR COMPANY
  4. Remove the bolts and the degas bottle.

    Torque: 48 lb.in (5.4 Nm)

GFD717619Courtesy of FORD MOTOR COMPANY