LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2022 >> E-Transit Van Cargo Extended >> Repair and Diagnosis >> Electrical >> Gauges >> Instrumentation, Message Center And Warning Chimes (Diagnosis And Testing) >> Diagnosis And Testing >> Instrumentation, Message Center and Warning Chimes - 3.5L Duratec (202kW/275PS)/3.5L EcoBoost (235kW/320PS) >> Pinpoint Tests >> Pinpoint Test Av: The Chime Only Sounds From The IPC (Instrument Panel Cluster)

Pinpoint Test Av: The Chime Only Sounds From The IPC (Instrument Panel Cluster)

  1. Normal Operation and Fault Conditions 

    REFER to: Warning Chimes - 3.5L Duratec (202kW/275PS)/3.5L EcoBoost (235kW/320PS) - System Operation and Component Description .

    Possible Sources 

    • Wiring, terminals or connectors
    • Communication concern
    • ACM concern

  2. AV1 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST

    • Ignition ON.

    • Using a diagnostic scan tool, perform the IPC self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to Diagnostic Trouble Code (DTC) Chart .
    No  GO to  AV2
  3. AV2 PERFORM THE ACM (AUDIO FRONT CONTROL MODULE) SELF-TEST

    • Using a diagnostic scan tool, perform the ACM self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Information and Entertainment System - Vehicles With: SYNC 3 Lite, Vehicles Without: SYNC Part 2.
    No  GO to  AV3
  4. AV3 CHECK FOR CORRECT ACM (AUDIO FRONT CONTROL MODULE) OPERATION

    • Ignition OFF.

    • Disconnect and inspect all the ACM connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the ACM connectors. Make sure they seat and latch correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new ACM.
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.