LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2021 >> Mustang Mach-E Select, AWD >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel And Interior Switches Illumination >> Diagnosis And Testing >> Instrument Panel and Interior Switches Illumination >> Pinpoint Test >> Pinpoint Test J: The IPC (Instrument Panel Cluster) Illumination Is Inoperative Or Does Not Dim

Pinpoint Test J: The IPC (Instrument Panel Cluster) Illumination Is Inoperative Or Does Not Dim

  1. Refer to INSTRUMENT CLUSTER for schematic and connector information.

    Normal Operation and Fault Conditions 

    REFER to: Instrument Panel and Interior Switches Illumination - System Operation and Component Description .

    Possible Sources 

    • Communication network concern
    • Wiring, terminals or connectors
    • IPC

  2. J1 PERFORM A NETWORK TEST

    • Ignition ON.

    • Using a diagnostic scan tool, perform a network test.

    Does the IPC pass the network test? 

    Yes  GO to  J2
    No  DIAGNOSE a concern with the network. REFER to: Controller Area Network (CAN) Module Communications Network .
  3. J2 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION

    • Disconnect and inspect all IPC and related in-line connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the IPC and related in-line connectors and all previously disconnected illumination system connectors. Make sure all connectors seat and latch correctly.

    • Operate the system to determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPC. REFER to: Instrument Panel Cluster (IPC) .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.