Pinpoint Test B: The Battery Charge (State Of Charge) Gauge Is Inoperative
- Normal Operation and Fault Conditions
See Battery Charge (State of Charge) Gauge. REFER to: Instrument Panel Cluster (IPC) - System Operation and Component Description .
Possible Sources
- Communication concern
- GWM
- BECM
- SOBDMC
- IPC
- B1 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST
- Using a diagnostic scan tool, perform the IPC self-test.
- Check for recorded Diagnostic Trouble Codes (DTCs).
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to Diagnostic Trouble Code (DTC) Chart . No GO to B2 - B2 PERFORM THE BECM (BATTERY ENERGY CONTROL MODULE) SELF-TEST
- Using a diagnostic scan tool, perform the BECM self-test.
- Check for recorded Diagnostic Trouble Codes (DTCs).
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: High Voltage Battery, Mounting and Cables . No GO to B3 - B3 PERFORM THE SOBDMC (SECONDARY ON-BOARD DIAGNOSTIC CONTROL MODULE C) SELF-TEST
- Using a diagnostic scan tool, perform the SOBDMC self-test.
- Check for recorded Diagnostic Trouble Codes (DTCs).
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to the Master DTC Chart. No GO to B4 - B4 CHECK THE GWM (GATEWAY MODULE A) DIAGNOSTIC TROUBLE CODES (DTCS)
- Using a diagnostic scan tool, check the GWM Continuous Memory Diagnostic Trouble Codes (DTCs).
Are any Diagnostic Trouble Codes (DTCs) recorded?
Yes REFER to: Controller Area Network (CAN) Module Communications Network . No GO to B5 - B5 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION
- Ignition OFF.
- Disconnect and inspect the IPC connector.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the IPC connector. Make sure it seats and latches correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
Yes CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPC. REFER to: Instrument Panel Cluster (IPC) . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.