LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2021 >> Explorer ST >> Repair and Diagnosis >> Accessories & Equipment >> Drivers Assistance Systems - ADAS >> Parking Aid - Vehicles With: Parking Aid Camera >> Diagnosis And Testing >> Parking Aid >> Pinpoint Test(s) >> Pinpoint Test Al : U1000:11

Pinpoint Test Al : U1000:11

  1. Normal Operation and Fault Conditions 

    DTC Fault Trigger Conditions 

    DTC Description Fault Trigger Condition
    IPMB U1000:11 Solid State Driver Protection Active -Driver Disabled: Circuit Short To Ground Sets in the IPMB when the IPMB repetitive excessive current draw for the audible parking aid system.

    Possible Sources 

    • Wiring
    • Parking aid sensor
    • Active park assist sensor
    • IPMB

  2. AL1 CHECK FOR DIAGNOSTIC TROUBLE CODES (DTCS) FROM THE IPMB (IMAGE PROCESSING MODULE B) SELF-TEST

    • Ignition ON.

    • Using the diagnostic scan tool, clear the Diagnostic Trouble Codes (DTCs).

    • Wait 10 seconds.

    • Using the diagnostic scan tool, perform the IPMB self-test.

    Are any DTC other than U1000:11 retrieved? 

    Yes  RETRIEVE and REPAIR all other IPMB Diagnostic Trouble Codes (DTC). REFER to Diagnostic Trouble Code (DTC) Chart .
    No  GO to  AL2
  3. AL2 CHECK FOR CORRECT IPMB (IMAGE PROCESSING MODULE B) OPERATION

    • Ignition OFF.

    • Disconnect and inspect the IPMB connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the IPMB connectors. Make sure they seat and latch correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPMB. REFER to: Image Processing Module B (IPMB) .
    No  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. ADDRESS the root cause of any connector or pin issues.