Pinpoint Test AQ : P2533:62
- Normal Operation and Fault Conditions
REFER to: Electric Powertrain Control - System Operation and Component Description .
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition SOBDMC P2533:62 Ignition Switch On/Start Position Circuit: Signal Compare Failure This DTC sets when the module is unable to shut off during key-off. Possible Sources
- Wiring, terminals or connectors
- BCM issue
- AQ1 CHECK THE BATTERY AND CHARGING SYSTEM
- Check the 12 volt battery and charging system voltages. REFER to: Charging System - Overview .
Are the battery and charging system voltages within specification?
Yes GO to AQ2 No REPAIR as necessary. REFER to: Charging System - Overview . CLEAR the Inverter System Controller (ISC) DTCs. REPEAT the self-test. - AQ2 CHECK THE ISP-R VPWR CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect BCMC C1035B.
- Disconnect Inverter System Controller (ISC) C1458A.
- Measure and record:
Positive Lead Measurement / Action Negative Lead C1035B-47 C1458A-K2
Is the resistance less than 5 ohms?
Yes GO to AQ3 No REPAIR the open circuit. - AQ3 CHECK THE ISP-R CIRCUIT FOR A SHORT TO VOLTAGE
- Ignition ON.
Is any voltage present?
Yes REPAIR the short circuit. CLEAR the DTCs and REPEAT the self-test. No GO to AQ4 - AQ4 RECHECK FOR DTC (DIAGNOSTIC TROUBLE CODE) P2533:62
- Ignition OFF.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the BCMC connectors. Make sure they seat and latch correctly.
- Reconnect the Inverter System Controller (ISC) connectors. Make sure they seat and latch correctly.
- Ignition ON.
- Ignition OFF.
- Wait two minutes.
- Ignition ON.
- Using a diagnostic scan tool, clear the BCMC and Inverter System Controller (ISC).
- Ignition OFF.
- Start the engine.
- Using a diagnostic scan tool, run the BCMC and Inverter System Controller (ISC) self-tests.
Is DTC P2533:62 present?
Yes Refer to Pinpoint Tests Z: Intermittent . No The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.