Degas Bottle: Removal

WARNING: This page is about a different variant/trim than selected.
WARNING: Always allow the engine to cool before opening the cooling system. Do not unscrew the coolant pressure relief cap when the engine is operating or the cooling system is hot. The cooling system is under pressure; steam and hot liquid can come out forcefully when the cap is loosened slightly. Failure to follow these instructions may result in serious personal injury.
NOTE: Removal steps in this procedure may contain installation details.
  1. GFD513072Courtesy of FORD MOTOR COMPANY
    GFD125800Courtesy of FORD MOTOR COMPANY
    WARNING: When releasing the cooling system pressure, cover the coolant expansion tank cap with a thick cloth.

    Release the cooling system pressure by slowly turning the degas bottle cap between 2 and 3 turns and remove the degas bottle cap.

    GFD513072Courtesy of FORD MOTOR COMPANY
  2. Using general tools clamp the lower expansion tank hose and syphon the engine coolant from the expansion tank. Use the General Equipment: Fluid Suction Gun, Use the General Equipment: Locking Pliers
    GFD513073Courtesy of FORD MOTOR COMPANY
    • Detach the electrical wiring harness retainer.

    • Release the clamps and disconnect the coolant hoses. Use the General Equipment: Hose Clamp Remover/Installer

    GFD513074Courtesy of FORD MOTOR COMPANY
    1. Remove the bolt.

      Torque: 44 lb.in (5 Nm)

    2. Remove the degas bottle.
GFD513075Courtesy of FORD MOTOR COMPANY