Pinpoint Test Y: B1087:83 Or B1087:87: Notes
Refer to Remote Keyless Entry and Alarm for schematic and connector information.
Normal Operation and Fault Conditions
The DDM communicates with the DRDM over a LIN circuit. In the event the DRDM fails, the LHR power window and power door lock become inoperative.
The PDM communicates with the PRDM over a LIN circuit. In the event the PRDM fails, the RHR power window and power door lock become inoperative.
DDM/ PDM DTC Fault Trigger Conditions
| DTC | Description | Fault Trigger Conditions |
|---|---|---|
| B1087:83 | LIN Bus "A": Value Of Signal Protection Calculation Incorrect | Sets by the DDM and PDM when a communication fault is detected from the communication from the corresponding RDM. |
| B1087:87 | LIN Bus "A": Signal Invalid | Sets by the DDM and PDM when a communication fault is detected from the communication from the corresponding RDM. |
Possible Causes
- Fuse
- Wiring, terminals or connectors
- RDM
- DDM
- PDM
- BCM
Visual Inspection and Diagnostic Pre-checks
- Check the BCM fuse 29 (30A) and fuse 30 (30A) and make sure they are OK.