Home >> Ford >> 2021 >> Expedition Platinum, 4WD >> Repair and Diagnosis >> External Pages >> Different car >> Section 42 (Exterior Lighting System) >> Diagnosis And Testing >> Headlamps >> Pinpoint Tests >> Pinpoint Test M : Both Lower High Beams Are On Continuously - Vehicles With Halogen Headlamps >> Pinpoint Test M : Both Lower High Beams Are On Continuously - Vehicles With Halogen Headlamps

Pinpoint Test M : Both Lower High Beams Are On Continuously - Vehicles With Halogen Headlamps

WARNING: This page is about a different car, the 2018 Ford F-550 Super Duty, 2018 Ford F-450 Super Duty, 2018 Ford F-350 Super Duty, and 2018 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.

  1. M1 CHECK HIGH BEAM VOLTAGE SUPPLY CIRCUIT FOR A SHORT TO VOLTAGE

    • Ignition OFF.

    • Disconnect: BCMB C263C .

    • Disconnect: Inoperative LH Headlamp C1509B or RH Headlamp C1510B .

    • Ignition ON.

    • Measure:
      Positive Lead Measurement / Action Negative Lead
      C1509B-3
      GFD200696Courtesy of FORD MOTOR COMPANY
      Ground

    Is any voltage present? 

    Yes  REPAIR the circuit.
    No  GO to  M2
  2. M2 CHECK FOR CORRECT BCMB (BODY CONTROL MODULE B) OPERATION

    • Disconnect and inspect all BCMB connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the BCMB connectors. Make sure they seat and latch correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new BCMB.
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.