Transmission Fluid Cooler Coolant Control Valve: Removal

NOTE: Removal steps in this procedure may contain installation details.
  1. Remove the front bumper cover. Refer to: Front Bumper Cover
  2. GFD588194Courtesy of FORD MOTOR COMPANY
    GFD185482Courtesy of FORD MOTOR COMPANY
    WARNING: When releasing the cooling system pressure, cover the coolant expansion tank cap with a thick cloth to prevent the possibility of scalding. Failure to follow this instruction may result in personal injury.

    Loosen the pressure relief cap.

    GFD588194Courtesy of FORD MOTOR COMPANY
  3. Disconnect the coolant control valve electrical connector.
    GFD588195Courtesy of FORD MOTOR COMPANY
  4. Clamp off the coolant control valve hoses.
    GFD588196Courtesy of FORD MOTOR COMPANY
  5. Release the clamps and disconnect the coolant hoses. Use the General Equipment: Hose Clamp Remover/Installer
    GFD588197Courtesy of FORD MOTOR COMPANY
  6. Remove the nuts and the transmission fluid cooler control valve.

    Torque: 93 lb.in (10.5 Nm)

GFD588198Courtesy of FORD MOTOR COMPANY