LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2021 >> Edge Titanium, FWD >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrumentation, Message Center And Warning Chimes (2 Of 2) >> Diagnosis And Testing >> Instrumentation, Message Center and Warning Chimes >> Pinpoint Tests >> Pinpoint Test BD: The Parking Brake Warning Chime Is Inoperative >> Pinpoint Test BD: The Parking Brake Warning Chime Is Inoperative

Pinpoint Test BD: The Parking Brake Warning Chime Is Inoperative

  1. BD1 CHECK THE SEATBELT WARNING CHIME OPERATION

    • Ignition OFF.

    • Ignition ON.

    • Unbuckle the driver seatbelt.

    • Monitor the seatbelt warning chime when the ignition is transitioned from OFF to RUN for 6 seconds.

    Does the seatbelt warning chime operate for approximately 6 seconds? 

    Yes  GO to  BD2
    No  GO to  BD5
  2. BD2 CHECK THE BRAKE WARNING INDICATOR FOR CORRECT OPERATION

    • Apply the parking brake.

    • Observe the brake warning indicator.

    Does the brake warning indicator illuminate? 

    Yes  GO to  BD3
    No  GO to Pinpoint Test O 
  3. BD3 PERFORM THE IPC (INSTRUMENT PANEL CLUSTER) SELF-TEST

    • Using a diagnostic scan tool, perform the IPC self-test.

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to DTC Chart: DTC Chart: Instrument Panel Cluster (IPC) .
    No  GO to  BD4
  4. BD4 CHECK THE GWM (GATEWAY MODULE A) DIAGNOSTIC TROUBLE CODES (DTCS)

    • Using a diagnostic scan tool, check the GWM Continuous Memory Diagnostic Trouble Codes (DTCs).

    Are any Diagnostic Trouble Codes (DTCs) recorded? 

    Yes  REFER to: Controller Area Network (CAN) Module Communications Network
     
    No  DIAGNOSE all BCM Diagnostic Trouble Codes (DTCs). REFER to: Body Control Module (BCM)
     
  5. BD5 CHECK FOR CORRECT IPC (INSTRUMENT PANEL CLUSTER) OPERATION

    • Ignition OFF.

    • Disconnect and inspect the IPC connector.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the IPC connector. Make sure it seats and latches correctly.

    • Operate the system and determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable service articles: TSB, GSB or SSM, FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new IPC. REFER to: Instrument Panel Cluster (IPC) 
     
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.