LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2021 >> Bronco First Edition, 2D Utility >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Panel And Interior Switches Illumination >> Diagnosis And Testing >> Instrument Panel and Interior Switches Illumination >> Pinpoint Test >> Pinpoint Test M: The Sima (Switch Input Module A) Illumination Is Inoperative Or Does Not Dim

Pinpoint Test M: The Sima (Switch Input Module A) Illumination Is Inoperative Or Does Not Dim

  1. Refer to INSTRUMENT CLUSTER for schematic and connector information.

    Normal Operation and Fault Conditions 

    REFER to: Instrument Panel and Interior Switches Illumination - System Operation and Component Description .

    Possible Sources 

    • Communication network concern
    • Wiring, terminals or connectors
    • SIMA

  2. NOTE: For a hazard switch illumination concern, refer to GO to Pinpoint Test D 
  3. M1 PERFORM A NETWORK TEST

    • Ignition ON.

    • Using a diagnostic scan tool, perform a network test.

    Does the SIMA pass the network test? 

    Yes  GO to  M2
    No  DIAGNOSE a concern with the network. REFER to: Controller Area Network (CAN) Module Communications Network .
  4. M2 CHECK FOR CORRECT SIMA (SWITCH INPUT MODULE A) OPERATION

    • Disconnect and inspect all SIMA and related in-line connectors.

    • Repair:

      • corrosion (install new connector or terminals - clean module pins)
      • damaged or bent pins - install new terminals/pins
      • pushed-out pins - install new pins as necessary

    • Reconnect the SIMA and related in-line connectors and all previously disconnected illumination system connectors. Make sure all connectors seat and latch correctly.

    • Operate the system to determine if the concern is still present.

    Is the concern still present? 

    Yes  CHECK OASIS for any applicable service articles: TSB, GSB, SSM or FSA. If a service article exists for this concern, DISCONTINUE this test and FOLLOW the service article instructions. If no service articles address this concern, INSTALL a new SIMA. REFER to: SWITCH INPUT MODULE A (SIMA) .
    No  The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.