Pinpoint Test Q : DTC U3000:49 Or U201A:55 Or U2300:56
- Normal Operation and Fault Conditions
REFER to: Body Closures - System Operation and Component Description .
DTC Fault Trigger Conditions
DTC Description Fault Trigger Condition RGTM U3000:49 Control Module: Internal Electronic Failure This DTC sets when the RGTM detects an internal failure RGTM U201A:55 Control Module Main Calibration Data: Not Configured This DTC sets when the RGTM has not been programmed or incorrectly programmed. RGTM U2300:56 Central Configuration: Invalid/Incompatible Configuration This DTC sets when the RGTM has not been programmed or incorrectly programmed. Possible Sources
- RGTM
- Q1 CHECK FOR DTCS U201A:55 OR U2300:56
- Check vehicle service history for recent service actions related to the RGTM.
- Ignition ON
- Using the diagnostic scan tool, clear the DTC.
- Wait 10 seconds.
- Using a diagnostic scan tool, carry out the RGTM self test.
Is DTCs U3000:49 present?
Yes INSTALL a new RGTM. REFER to: Rear Gate Trunk Module (RGTM) . No For DTCs U201A:55 or U2300:56, GO to Q2 - Q2 INSTALL BCM (BODY CONTROL MODULE) PMI (PROGRAMMABLE MODULE INSTALLATION)
- Using a diagnostic scan tool, clear the DTC
- Following scan tool instructions, INSTALL BCM As-Built data from PTS.
Is DTCs U201A:55 OR U2300:56 present?
Yes CHECK OASIS for any applicable Technical Service Bulletins (TSBs). If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no Technical Service Bulletins (TSBs) address this concern, INSTALL a new RGTM. REFER to: Rear Gate Trunk Module (RGTM) . No The system is operating correctly at this time. The concern may have been caused due to module connections. ADDRESS the root cause of any connector or pin issues.